GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Observation-example

This is the narrative for the resource. See also the XML or JSON format.


Generated Narrative with Details

id: observation-example

status: final

code: Hemoglobin [Mass/volume] in Venous blood (Details : {LOINC code '30350-3' = 'Hemoglobin [Mass/volume] in Venous blood', given as 'Hemoglobin [Mass/volume] in Venous blood'})

subject: Patient/example

effective: 02/04/2013 10:30:10 AM --> 05/04/2013 10:30:10 AM

issued: 03/04/2013 3:30:10 PM

value: 7.2 g/dl (Details: http://unitsofmeasure.org code g/dL = '??')

interpretation: Below low normal (Details : {http://hl7.org/fhir/v2/0078 code 'L' = 'Low', given as 'Low'})

bodySite: Superficial forearm vein (Details : {SNOMED CT code '308046002' = '308046002', given as 'Superficial forearm vein'})

method: Injection to forearm (Details : {SNOMED CT code '120220003' = '120220003', given as 'Injection to forearm'})


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.